All olympus ep1 case wholesalers & olympus ep1 case manufacturers come from members. We doesn't provide olympus ep1 case products or service, please contact them directly and verify their companies info carefully.
Total 20 products from olympus ep1 case Manufactures & Suppliers |
|
Brand Name:OLYMPUS Model Number:OLYMPUS A-4801A OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE, 10MM,0°, AUTOCLAVABLE WSTERILIZATION CASE Description: Brand Name: OLYMPUS Name: OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE PN: A-4801A Notes from company: Order: Medical parts and equipment with bulk stock and competitive ... |
Guangzhou YIGU Medical Equipment Service Co.,Ltd
Guangdong |
Brand Name:TMTeck Place of Origin:China ...OLYMPUS NDT standard PA wedges FEATURES Waterproof Small dimensions Encoder resolution is engraved on the wheel Removable encoder wheel Double O-ring tire for better adherence Metallic strain relief for cable protection Spring-loaded pin for encoder attachment Two M3 threaded holes on top of the casing... |
TMTeck Instrument Co., Ltd
Beijing |
Brand Name:Olympus Model Number:CF-Q260 ... to be changed incrementally by manipulating a flexibility adjustment ring. This innovative feature allows the scope to be adjusted on a case-by-case basis, to meet the unique anatomical needs of the patient and the handling preferences of the physician. |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Brand Name:OLYMPUS Model Number:A-4801A Place of Origin:Original OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE, 10MM,0°, AUTOCLAVABLE WSTERILIZATION CASE YIGU Med Feature Yigu med is a professional medical equipment service and accessories/parts selling company Operating with over 10 years ... |
Guangzhou YIGU Medical Equipment Service Co.,Ltd
Guangdong |
Brand Name:Olympus Model Number:CF-H190L OLYMPUS CF-H190L colonoscope SN: 240****. Test results: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:CV-190 Olympus CV-190 processor. Fault: Normal working, but error for white balance. The chips missing on main control panel (PN:DV641901), and short circuit. Solution: Repair main control panel. We provide trading and service of Ultrasound Unit/Transduce,Dynamic... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:CF-240AI Olympus CF-240AI Colonoscope for repair, SN:2521***. Fault: No image. Leakage, insert tube, biopsy channel, light guide tube and light bundle aging,no angle, knob tight,etc. Solution: Grade A repair. (Grade A repair is include replace CCD,light guide tube,... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:CF-240L Olympus CF-240L Colonoscope for repair, SN:2900***. Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch,etc. Solution: Replace rubber, objective lens, C cover. Adjust the angle. Repair time: 5 ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:BF-1T40 Olympus BF-1T40 Bronchoscope for repair, SN:1221***. Fault: insert tube bited, rubber leak,image fuzzle, image bundle break,etc. Solution: Grade A repair. (Grade A repair is include replace image bundle,light guide tube,insert tube,forcept tube and rubber... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:CHF-P20Q Olympus CHF-P20Q endoscope for repair. SN: 272**** Fault: Insert tube cracked; Rubber leakage; Image with black point and cracked; Angulation tight; Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:LTF-160 OLYMPUS LTF-160 thoracoscope for repair,SN: 270****. Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:BF-XP160F OLYMPUS BF-XP160F fiber scope, SN:280**** Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:GIF-Q180 OLYMPUS GIF-Q180 gastroscope, SN: 270**** Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:GIF-1TQ160 OLYMPUS GIF-1TQ160 gastroscope , SN:270**** Fault: 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:CF-2T160L OLYMPUS CF-2T160L scope, SN:210**** Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. Solution: Replace wires, helix ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Model Number:OTV-S6H-1D OLYMPUS OTV-S6H-1D camera head,SN:700**** Fault: 1.With image. 2. Cable aging, interference. Solution: Replace new cable. Repair cost: $*** |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Brand Name:Olympus Model Number:BF-XP160F OLYMPUS BF-XP160 Ffiber bronchoscope, SN:280****. Fault: 1.Poor imageclarity, image bundle aging; 2.Light bundlebreak 35%; 3.Insert tubemild aging; 4.Biopsy tubewear; 5.Wires wear. Solution: Replace image bundle, light bundle, insert tube, biopsy tube, ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Brand Name:Olympus Model Number:CF-Q180AI OLYMPUS CF-Q180AI colonoscope,SN:280****. Test result: 1. With image ; 2. 25% light bundle break ; 3. The insert tube is slightly aged, leakage at the hardness adjust position; 4. Biopsy tube wear; 5. Bending section deformation, down angle failure; 6.... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Brand Name:Olympus Model Number:GIF-Q150 OLYMPUS GIF-Q150gastroscope, SN:270****. Test result: 1. With image; 2. Light bundlebreak badly; 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and helix tube abrasion; 6. Rubberwithout glue. Solution: ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |
Brand Name:Olympus Model Number:TJF-Q180V OLYMPUSTJF-Q180V duodenoscope, SN: 270****. Test result: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. Maintenance: Suggest toreplace biopsy tube, bending ... |
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Hongkong |