37KW Variable Frequency Converter , Variable Frequency Drive Inverter High Starting Torque

Categories Vector Frequency Inverter
Brand Name: Noker
Model Number: JAC580-037G-4-5030
Certification: CE、SGS、ISO9001
Place of Origin: China
MOQ: 1 set
Price: To be discussed later
Supply Ability: 1000 set per month
Delivery Time: 5-8 work days
Packaging Details: Carton Packing
Protection: Perfect Protection Function
Vector control: Vector control for various motor
Non-speed sensor vector control: The newest non-speed sensor vector control
Starting torque: High starting torque
Motor Type: Asynchronous And Synchronous Electric Motor
Three anti-spraying: All circuit boards are Three anti-sprayed
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    37KW Variable Frequency Converter , Variable Frequency Drive Inverter High Starting Torque

    37KW Squirrel-Cage Asynchronous And Synchronous Electric Motor Non-speed Sensor Vector Frequency Inverter


    37KW Squirrel-Cage Asynchronous And Synchronous Electric Motor Non-speed Sensor Vector Frequency Inverter series frequency Inverter, as a general current vector frequency Inverter with high performance,dedicated to the induction motor drive.Drivers available for packaging, food, fans, pumps and a variety of automated production equipment.


    Features


    Support the vector control for various motors.

    1. Support the asynchronous motor and the vector control for an synchronous motor.

    2. Support the vector control for permanent magnet synchronous motor without absolute position feedbacks.

    3. Support various encoders,differential encoder,open collector encoder and rotary encoder.

    The newest non-speed sensor vector control

    1. The non-speed sensor vector control can do locked-rotor movement and it can output 150% rated moment of force at 0.5Hz.

    2. The non-speed sensor vector control can reduce the sensitivity of motor parameter and improve the current applicability.

    3. It can be used for winding control,load distribution under various motors dragging one load and other occasions.

    Characteristics of high starting torque and superior responsiveness

    1. The 150% starting torque can be provided at 0.5Hz ( without the vector control for sensor ) , while 180% torque at zero speed (with the vector control for sensor) can be provided at 0 Hz.

    2. Without the vector control for sensor, the torque is <20 ms. With the vector control for sensor, the torque is <5 ms


    Specification


    ItemSpecifications
    Standard functionsInput voltage range

    Voltage continuous fluctuation: ±10%

    Voltage transient fluctuation: -15% ~ +10%

    Input frequency50Hz/60Hz Fluctuation range: ±5%
    Maximum frequency

    Vector control: 0~300Hz

    V/F control: 0~320Hz

    Carrier frequency

    0.5Khz ~16KHz

    The carrier frequency is automatically adjusted based on the load features.

    Input frequency resolution

    Digital setting: 0.01Hz

    Analog setting: maximum frequency ±0.025%

    Control mode

    Sensorless fux vector control (SVC)

    Closed-loop vector control (FVC)

    Voltage/Frequency (V/F) control

    Start-up torque

    G type: 0.5Hz/150% (SVC); 0Hz/180% (FVC)

    P type: 0.5Hz/100%

    Speed range1:100 (SVC)1:1000 (FVC)
    Speed stability accuracy±0.5% (SVC)±0.02% (FVC)
    Torque control accuracy±5% (SVC)

    w

    Standard functions

    Overload capacity

    G type: 60s for 150% of the rated current,

    3s for 180% of the rated current.

    P type: 60s for 120% of the rated current,

    3s for 150% of the rated current.

    Torque boostFixed boost; Customized boost 0.1%~30.0%
    V/F curve

    Straight-line V/F curve; Multi-point V/F curve;

    N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, Square).

    V/F separationTwo types: complete separation; half separation
    Torque limit and control

    It can limit the torque automatically and prevent frequent over current tripping during the running process.

    Torque control can be implemented in the FVC mode.

    DC braking

    DC braking frequency: 0.00Hz to maximum frequency

    Braking time: 0.0s ~ 36.0s

    Braking action current value: 0.0% ~ 100.0%

    JOG control

    JOG frequency range: 0.00Hz ~ 50.00Hz

    JOG acceleration/deceleration time: 0.0s ~ 6500.0s

    Simple PLC,Onboard multiple preset speedsIt implements up to 16 speeds via the simple PLC function or combination of X terminal states.
    Onboard PIDIt realizes process-controlled closed loop control system easily.
    Auto voltage regulation (AVR)It can keep constant output voltage automatically when the mains voltage changes.
    Overvoltage/Overcurrent stall controlThe current and voltage are limited automatically during the running process so as to avoid frequency tripping due to overvoltage/overcurrent.
    Individualized functionsHigh performanceControl of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
    Torque control modeSpeed control and torque control mode, can realize the open-loop tension control.
    Power dip ride throughThe load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.
    Individualized functionsRapid current limitIt helps to avoid frequent overcurrent faults of the AC drive.
    Virtual IOFive groups of virtual XDO can realize simple logic control.
    Fixed length controlAccording to the number of pulses to achieve constant length control.
    Timing controlTime range: 0.0Min ~ 6500.0Min
    Multi-motor switchoverFour motors can be switched over via four groups of motor parameters.
    Multiple communication protocolsIt supports communication via Modbus-RTU, PROFIBUS-DP, CANlink and CANopen.
    Motor overheat protectionThe optional I/O extension card enables AI3 to receive the motor temperature sensor input so as to realize motor overheat protection.
    Multiple encoder typesIt supports various encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/COS encoder.
    RUNRunning command sourceOperation panel; control terminals; Serial communication pot. You can perform switchover between these sources in various ways.
    Frequency source AThere are a total of 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. You can perform switchover between these sources in various ways.
    Frequency source BThere are ten frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis.
    Input terminal

    Standard:

    5 digital input(X) terminals, one of which supports up to 100KHz high-speed pulse input;

    2 analog input(AI) terminals, one of which only supports 0 ~ 10V voltage input 4 ~ 20mA current input.

    Expanding capacity:

    5 X terminals;

    1 AI terminal that supports -10 ~ 10V voltage input.

    Output terminal

    Standard:

    1high-speed pulse output terminal (open-collector) that supports 0 ~ 100KHz square wave signal output;

    1 digital output (DO) terminal; 1 relay output terminal;

    1 analog output (AO) terminal that supports 0 ~ 20mA current output or 0 ~ 10V voltage output.

    Expanding capacity:

    1 DO terminal; 1 relay output terminal;

    1 AO terminal that supports 0 ~ 20mA current output or 0 ~ 10V voltage output.

    Display and operation on the operation panelLED displayIt displays the parameters.
    Key locking and function selectionIt can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function.
    Protection modeMotor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection , overheat protection and overload protection
    Optional partsLCD operation panel, braking unit, I/O extension card 1, I/O extension card 2, user programmable card, RS485 communication card, PROFIBUS-DP communication card, CANlink communication card, CANopen communication card, differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card
    EnvironmentInstallation locationIndoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
    AltitudeLower than 1000m
    Ambient temperature

    -10℃ to +40℃

    (de-rated if the ambient temperature is between 40℃ and 50℃)

    HumidityLess than 95% RH, without condensing
    VibrationLess than 5.9m/s2 (0.6g)
    Storage temperature-20℃ to +60℃
    IP levelIP20
    Pollution degreePD2
    Power distribution systemTN, TT

    Wiring mode control loop



    The function description of control terminal


    Category

    Terminal symbol

    Terminal name

    Function description

    Power supply+10V-GNDExternal connection of +10V power supply

    Provide power supply of +10V externally, with maximize output current: 10mA

    It is generally used as working power supply for external potentiometer and the resistance range of potentiometer is 1kΩ~5k Ω

    +24V-COMExternal connection of +24V power supply

    +24V power supply is provided outwards and generally used as the working power supply for digital input/output terminal and the power supply for external sensor

    Maximum output current: 200mA

    OPInput terminal of external power supply

    The factory default is connection to+24V

    When an external signal is used to drive DI1~DI5, OP shall be connected to external power supply and disconnected from+24V power supply terminal

    Analog inputAI1-GNDAnalog Input Terminal 1

    1. Input voltage range: DC 0V~10V

    2. Input resistance: 22kΩ

    AI2-GNDAnalog Input Terminal 2

    1. Input range: 4mA~20mA,

    2. Input resistance: 500Ω for current input.

    Digital inputDI1- OP

    Digital

    Input 1

    1. Optical coupler isolation, with bipolar input

    2. Input resistance: 2.4kΩ

    3. Voltage range in input level: 9V~30V

    DI2- OP

    Digital

    Input 2

    DI3- OP

    Digital

    Input 3

    DI4- OP

    Digital

    Input 4

    DI5- OPHigh-speed pulse input terminal

    Apart from the characteristics of DI1~DI5, it may be used as high-speed pulse input channel.

    Maximum input frequency: 50kHz

    Analog outputAO1-GND

    Analog

    Output 1

    Jumper J5 on the control panel shall determine voltage or current output.

    Output voltage range: 0V~10V

    Output current range: 0mA~20mA

    Relay outputT/A-T/COpen terminal

    Contact drive capacity:

    25V ac,3A,COSØ=0.4 .

    30Vdc ,1A

    Communication interface485+,485-ModbusModbus communication interface, non-isolated output

    Factory



    Daily maintenance


    Due to the influences of temperature, humidity and dust in the environment and the effect of vibration, the internal components of frequency converter are resulted to aging, which causes the potential occurrence of the failure for frequency converter or the decrease of the service life for frequency converter. Therefore, it is necessary to implement the daily and regular maintenance to the frequency converter.
    Daily inspection items:
    1) Whether the sound changes abnormally when the motor is running
    2) Whether vibration occurs when the motor is running
    3) Whether the installation environment for frequency converter changes
    4) Whether the cooling fan of frequency converter functions normally
    5) Whether the frequency converter is overheated
    6) Daily cleaning:
    7) Always keep the frequency converter in clean state.
    8) Effectively remove the dust on the surface of frequency converter, thus preventing the dust enter into the inside of the frequency converter. Especially for the metal dust
    9) Effectively eliminate the oil in the cooling fan of frequency converter.
    Daily maintenance
    Please make regular inspections to the places which are hard to be inspected during running.
    Regular inspection items:
    1) Inspect the air channel and clean it regularly
    2) Inspect whether the screw is loose
    3) Inspect whether the frequency converter suffers from corrosion
    4) Inspect whether the terminal block has the arc traces
    5) Insulation test for major loop
    Remind: when using the megameter (use DC 500V megameter please) to measure the insulation resistance, the major loop line needs to be disconnected with the frequency converter. Do not use the insulation resistance meter to measure the insulation of the control loop. No need to conduct the high voltage test (it is already completed in delivery).