Fire Resistant Black Sheath 4 Core Copper Armoured Cable

Categories Armoured Power Cable
Brand Name: CHINT
Model Number: YJV22
Certification: CCC/KEMA/SGS
Place of Origin: CHINA
MOQ: Negotiable
Price: Negotiable
Supply Ability: 500KM/Month
Packaging Details: wooden/iorn drum
Name: Copper Armoured Cable
Feature: Fire Resistant
Outer Sheath: PVC/MDPE
Rated Voltage: 0.6/1kV
Sheath: Black Sheath
Port: Shanghai
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Fire Resistant Black Sheath 4 Core Copper Armoured Cable

Fire Resistant Black Sheath 4 Core Copper Armoured Cable

Copper Armoured Cable Application


For laying in tunels in door,tunnel,channel and underground.Able to bear external mechanical force,but unable to bear large pulling force.


Copper Armoured Cable Description


Conductor:Class 2

Insulation:XLPE

Sheath: PVC

Cable Speciification: Fire Resistant

Marking: Embossing Or Printing


Construction


Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228

Insulation : 90°C cross linked XLPE insulation complying with IEC 60502-1

Interlining: PVC type ST2 to IEC 60502, black

Armouring: STA(Steel-Tape Armouring)

Sheath : PVC type ST2 to IEC 60502, black


Standards:


International: IEC 60502, IEC 60228, IEC 60332, IEC 60754

China: GB∕T 12706.1-2008, GB∕T 19666-2005

Other standards such as BS,VDE and ICEA upon request


Copper Armoured Cable Technical data


Rated voltage: 0.6/1kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables


Copper Armoured Cable Technical Specifications


Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulationThickness of steel tapeSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×107/1.330.70.21.811.82651.833.57794
1×167/1.670.70.21.812.83381.153.5100120
1×257/2.100.90.21.814.54580.7273.5130155
1×357/2.480.90.21.815.65710.5243.5160185
1×5010/2.561.00.21.816.87120.3873.5195220
1×7014/2.561.10.21.818.79400.2683.5245270
1×9519/2.561.10.21.820.312090.1933.5300320
1×12024/2.561.20.21.822.014650.1533.5349365
1×15030/2.561.40.21.823.817570.1243.5400410
1×18537/2.561.60.21.825.921570.09913.5465465
1×24048/2.581.70.21.828.327320.07543.5550540
1×30060/2.581.80.21.930.933440.06013.5635610
1×40060/2.932.00.2234.442600.0473.5745695
1×50060/3.332.20.52.239.656730.03663.5860780
1×63060/3.762.40.52.344.071330.02833.5990880
2×1.51/1.380.70.21.812.323012.13.52031
2×2.51/1.760.70.21.813.12667.563.52741
2×41/2.230.70.21.814.03164.613.53553
2×61/2.740.70.21.815.03783.083.54566
2×107/1.330.70.21.817.55161.833.56390
2×167/1.670.70.21.819.56721.153.584117
2×257/2.100.90.21.822.99370.7273.5113151
2×357/2.480.90.21.825.211810.5243.5139181
2×5010/2.561.00.21.821.812810.3873.5161210
2×7014/2.561.10.21.924.817340.2683.5204257
2×9519/2.561.10.2227.522780.1933.5252310
2×12024/2.561.20.52.231.330950.1533.5291351
2×15030/2.561.40.52.334.537300.1243.5333393
2×18537/2.561.60.52.538.246180.09913.5385445
2×24048/2.561.70.52.642.258320.07543.5457516
2×30060/2.561.80.52.846.371420.06013.5527583
3×1.51/1.380.70.21.812.725612.13.52031
3×2.51/1.760.70.21.813.53027.563.52741
3×41/2.230.70.21.814.63674.613.53553
3×61/2.740.70.21.815.74493.083.54566
3×107/1.330.70.21.818.46271.833.56390
3×167/1.670.70.21.820.58381.153.584117
3×257/2.100.90.21.824.211910.7273.5113151
3×357/2.480.90.21.826.615280.5243.5139181
3×5010/2.561.00.21.925.518140.3873.5161210
3×7014/2.561.10.2229.024740.2683.5204257
3×9519/2.561.10.52.133.535980.1933.5252310
3×12024/2.561.20.52.336.743860.1533.5291351
3×15030/2.561.40.52.440.753320.1243.5333393
3×18537/2.561.60.52.544.665620.09913.5385445
3×24048/2.561.70.52.850.284140.07543.5457516
3×30060/2.561.80.52.954.9103060.06013.5527583
4×1.51/1.380.70.21.813.529112.13.52031
4×2.51/1.760.70.21.814.43487.563.52741
4×41/2.230.70.21.815.54304.613.53553
4×61/2.740.70.21.816.75343.083.54566
4×107/1.330.70.21.819.87581.833.56390
4×167/1.670.70.21.822.210271.153.584117
4×257/2.100.90.21.826.314790.7273.5113151
4×357/2.480.90.21.829.119140.5243.5139181
4×5010/2.561.00.2228.423340.3873.5161210
4×7014/2.561.10.52.133.635180.2683.5204257
4×9519/2.561.10.52.337.946380.1933.5252310
4×12024/2.561.20.52.441.857010.1533.5291351
4×15030/2.561.40.52.646.069120.1243.5333393
4×18537/2.561.60.52.751.085620.09913.5385445
4×24048/2.561.70.5357.7110520.07543.5457516
4×30060/2.561.80.53.162.7134790.06013.5527583
5×1.51/1.380.70.21.814.332812.13.52031
5×2.51/1.760.70.21.815.33977.563.52741
5×41/2.230.70.21.816.64974.613.53553
5×61/2.740.70.21.818.06233.083.54566
5×107/1.330.70.21.821.48951.833.56390
5×167/1.670.70.21.824.112251.153.584117
5×257/2.100.90.21.828.717800.7273.5113151
5×357/2.480.90.21.931.923290.5243.5139181
5×5019/1.861.00.22.131.928790.3873.5161210
5×7014/2.561.10.52.237.843270.2683.5204257
5×9519/2.561.10.52.442.857400.1933.5252310
5×12024/2.561.20.52.546.870270.1533.5291351
5×15030/2.561.40.52.752.185910.1243.5333393
5×18537/2.561.60.52.957.5106360.09913.5385445
5×24048/2.561.70.53.264.5136510.07543.5457516
5×30060/2.561.80.53.471.0167640.06013.5527583
3×2.5+1×1.51/1.760.70.21.814.13347.563.52741
3×4+1×2.51/2.230.70.21.815.24104.613.53553
3×6+1×41/2.740.70.21.816.45083.083.54566
3×10+1×67/1.330.70.21.819.07011.833.56390
3×16+1×107/1.670.70.21.821.69591.153.584117
3×25+1×167/2.100.90.21.825.313650.7273.5113151
3×35+1×167/2.480.90.21.827.416890.5243.5139181
3×50+1×2510/2.561.00.21.927.921150.3873.5161210
3×70+1×3514/2.561.10.2232.128960.2683.5204257
3×95+1×5019/2.561.10.52.237.442130.1933.5252310
3×120+1×7024/2.561.20.52.341.452510.1533.5291351
3×150+1×7030/2.561.40.52.445.061750.1243.5333393
3×185+1×9537/2.561.60.52.650.077310.09913.5385445
3×240+1×12048/2.561.70.52.856.098570.07543.5457516
3×300+1×15060/2.561.80.5361.3120420.06013.5527583
3×2.5+2×1.51/1.760.70.21.814.93697.563.52741
3×4+2×2.51/2.230.70.21.816.14574.613.53553
3×6+2×41/2.740.70.21.817.45733.083.54566
3×10+2×67/1.330.70.21.820.07851.833.56390
3×16+2×107/1.670.70.21.823.010921.153.584117
3×25+2×167/2.100.90.21.826.815560.7273.5113151
3×35+2×167/2.480.90.21.828.718740.5243.5139181
3×50+2×2510/2.561.00.2229.123840.3873.5161210
3×70+2×3514/2.561.10.52.134.435830.2683.5204257
3×95+2×5019/2.561.10.52.338.546920.1933.5252310
3×120+2×7024/2.561.20.52.442.559090.1533.5291351
3×150+2×7030/2.561.40.52.546.868890.1243.5333393
3×185+2×9537/2.561.60.52.752.587440.09913.5385445
3×240+2×12048/2.561.70.52.958.5110680.07543.5457516
3×300+2×15060/2.561.80.53.164.5135510.06013.5527583
4×2.5+1×1.51/1.760.70.21.815.13837.563.52741
4×4+1×2.51/2.230.70.21.816.44774.613.53553
4×6+1×41/2.740.70.21.817.75983.083.54566
4×10+1×67/1.330.70.21.820.78391.833.56390
4×16+1×107/1.670.70.21.823.511591.153.584117
4×25+1×167/2.100.90.21.827.716670.7273.5113151
4×35+1×167/2.480.90.21.930.421070.5243.5139181
4×50+1×2510/2.561.00.2229.525900.3873.5161210
4×70+1×3514/2.561.10.52.235.039000.2683.5204257
4×95+1×5019/2.561.10.52.339.351440.1933.5252310
4×120+1×7024/2.561.20.52.543.263860.1533.5291351
4×150+1×7030/2.561.40.52.648.376830.1243.5333393
4×185+1×9537/2.561.60.52.853.295660.09913.5385445
4×240+1×12048/2.561.70.5359.7122190.07543.5457516
4×300+1×15060/2.561.80.53.365.6149850.06013.5527583

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement


PACKING AND SHIPPING

All cable for exporting are well packed and protected by wooden drum or Wood and Steel Drum.

The packing material is depended on the weight and size of cable.

The good information, manufacture information, and the client's information is firmly printed on each size of drum.


After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosen according to weight of total loaded goods or as per the client's requirement.


Quality Fire Resistant Black Sheath 4 Core Copper Armoured Cable for sale
Send your message to this supplier
 
*From:
*To: Zhejiang CHINT Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0